FREE WORLDWIDE SHIPPINGTRACKING INCLUDEDSECURE PAYMENT
Freeshipping FX1N FX2N-24MT 6AD 2DA PLC industrial control board Special encrypt
✓ Paiement protégé✓ Livraison suivie✓ Canadian service

Maison · H-168205202892

Freeshipping FX1N FX2N-24MT 6AD 2DA PLC industrial control board Special encrypt

NouveauAvailable from Prime Living

Last unit available

233.99 CAD
Free worldwide shippingEstimated delivery to Canada: 4–10 business days
Product details
SKU
H-168205202892
Product code
H-168205202892
Condition
Neuf
Department
Maison
Brand
Shipping
Free worldwide shipping

COMPLETE INFORMATION

Product description

Product Description

Freeshipping FX1N FX2N-24MT 6AD 2DA PLC industrial control board Special encryption with 6 way NTC 10K temperature RS485 RTCFreeshipping FX1N FX2N-24MT 6AD 2DA PLC industrial control board Special encryption with 6 way NTC 10K temperature RS485 RTCFreeshipping FX1N FX2N-24MT 6AD 2DA PLC industrial control board Special encryption with 6 way NTC 10K temperature RS485 RTCBoard 14 points input 10 point transistor outputX0~X5 are high-speed input, can connect 1 channel AB encoder, default 12K, select 60KThe board is powered by DC 24V. Do not input AC or 220V directly.Supported instruction listFreeshipping FX1N FX2N-24MT 6AD 2DA PLC industrial control board Special encryptFreeshipping FX1N FX2N-24MT 6AD 2DA PLC industrial control board Special encryptAD input readFreeshipping FX1N FX2N-24MT 6AD 2DA PLC industrial control board Special encryptAnalog read instruction: RD3AAD range setting: D0 upper limit D1 lower limit (accounting for 2 registers) D0 non-fixed register, other registers can be usedWhen the above program example: When D10 data = 500, it means that the 5V analog signal input is read.Example: When D10 data = 1000, it means reading 10V analog signal input.When the range is not set: 0-10V corresponds to 40950-10V range setting technique: Case 1. For example, a 60 kPa pressure sensor, then we set the upper limit range (D0) to 6000. The lower limit range (D1) is set to 0.When D10 data = 3000 indicates the current pressure 3 kPaWhen D10 data = 5000 means the current pressure is 5 kPaCase 2. For example, an 8 meter water level sensor, then we set the upper limit range (D0) to 800. The lower limit (D1) is set to 0.When D10 data = 520 indicates the current 5.2 m water levelWhen D10 data = 465 indicates the current 4.65 m water level4-20MA range setting technique: Case 1. For example, a 50 kPa pressure sensor, then I set the upper limit range to 5000. The lower limit range is set to -1250 (the lower limit of the lower limit range is 1/1)When D10 data = 3500, the current pressure is 3.5 kPa.When D10 data = 4000, the current pressure is 4 kPa.Note: Since the PLC current signal is 0-20 mA, when setting the range, the lower limit range should be set to a negative number (MOV K-1250 D1)Since the initial state of the 4-20 mA sensor will be 4 mA, and all lower limit ranges are set to 1/1 of the upper limit, which is equivalent to removing 4 mA!NTC temperature readingNTC modification instructions: AD can be changed to thermal resistance type Temperature input: NTC 10K (-40-150 degrees Celsius) or NTC 50K (-40 ~ 209 degrees Celsius) can modify 6 channels at mostFreeshipping FX1N FX2N-24MT 6AD 2DA PLC industrial control board Special encryptNeed to buy (NTC-10K B value 3950 thermistor) (or NTC-50K B value 3950 thermistor)(Note: When the probe wire is too short, please do not connect other electronic wires. It is necessary to apply a wire with low impedance and strong anti-interference ability. Otherwise, the temperature will be unstable. It is recommended to set the length of the wire when purchasing the probe.)NTC temperature reading does not require setting rangeThe data is divided by 10, which is the actual temperature.When D10=500, it means the current temperature of the first road is 50°.When D10=437, it means the current temperature of the first road is 43.7°.When D11=800, it means the current temperature of the second road is 80°.When D11=-200, it means the current temperature of the second road is -20°.DA analog outputFreeshipping FX1N FX2N-24MT 6AD 2DA PLC industrial control board Special encryptAnalog output command: WR3ARange setting: The same method is used for analog input setting. When the range is not set, 0-10V corresponds to 4095.Column: When the D0 upper limit range is set to 1000 (the lower limit can be set to 0 by default)When D10=500, DA0 outputs 5V voltage.DA0 outputs 8V when D10=800DA1 outputs 3.4V when D11=340DA1 outputs 5.5V when 11=550

About Prime Living

Prime Living is a Canadian online store offering a carefully selected range of quality products for home, automotive, tools, outdoor living, electronics and more.

We are committed to fast order processing, secure packaging and reliable tracked shipping to provide an excellent shopping experience.

Shipping policy

We carefully handle each order to ensure your package arrives quickly and safely. Please note that factors such as weather, postal traffic, or carrier performance may occasionally cause delays beyond our control.

We provide free shipping and dispatch all orders within 2 business days of payment, often sooner. All shipments are sent via international express air shipping, with a tracking number provided so you can follow your order every step of the way.

. Please provide a physical address, as we do not ship to P.O. Boxes.

Returns

Your satisfaction is important to us. Hexlight offers a 14-day Free return policy: if you are not fully satisfied with your purchase, you may request either a full refund or an exchange. All return shipping costs are fully covered by us.

Condition

Brand New

Shipping

This item is shipped directly from our supplier in China with tracking.